Ensure that there is power to the furnace.
Furnace circuit breaker problems.
Overload due to loose electrical connection.
Can be caused by a bad wire or by power not reaching the thermostat.
This can be caused by a number of reasons.
Or replace the fuse.
Let s explain the above problems in more detail.
If the fan doesn t run try resetting the furnace circuit breaker.
Here s the next step in furnace troubleshooting.
Try turning the fan to on using the fan switch on the thermostat to test for power to furnace.
Short circuits in your furnace happen when a bare hot wire comes in contact with a neutral wire.
Your furnace may be tripping the circuit breaker because of one of these reasons.
There are issues with your furnace motor.
Still haven t found the problem.
The system s wiring usually wears down after years of use.
The compressor which sounds like a refrigerator and fan should be running.
Other issues that can contribute to an overworking furnace blower include home air leaks duct leaks and closed or blocked off air registers.
Another reason why your breaker is tripping is a faulty furnace motor.
Your furnace might share a breaker with another appliance that caused the trip or the circuit breaker itself may have.
Next check the outside condensing unit.
Don t keep resetting the breaker to turn the furnace back on until you fix the underlying problem.
Check the ssu switch it looks like a light switch on a gray box located at the furnace to be sure it is in the on position.
Breakers do go bad from time to time and cause nuisance trips.
If the machine doesn t power on check the circuit breaker.
Failed time delay relay.
The fix is to replace the breakers.
In some instances a tripped circuit breaker isn t your furnace s fault at all.
The circuit breaker is triggered or.
Check both the main electrical panel and any secondary subpanels that supply power to the unit.
Not enough power from the thermostat to the furnace.
A bad circuit breaker can be causing the furnace breaker to be tripping.
Overload due to furnace blower overworking.
If the fan still won t start call a pro the fixes shown here won t work.
2 be sure the furnace s circuit breaker is on or that its fuse has not blown.
If the circuit has blown or tripped reset the circuit breaker by flipping it all the way off and then on again.
A furnace that starts up but immediately trips the breaker can be caused by an electrical short circuit or ground fault inside of the furnace itself.
Check the circuit breakers at the electrical panel.
As a result shorts and other issues might occur therefore tripping the circuit breaker.
Unless you know what you are doing this will require the services of an electrician or hvac technician.
Common rv furnace problems rv furnace blower won t start.
If the furnace fan kicks in the problem isn t in the furnace.