Galvanized steel copper brass or csst corrugated stainless steel tubing also can be used in some areas but some utilities specifically prohibit the.
Gas main to meter meter to attic.
Secure the box to the wall according to manufacturer recommendations.
But the large mansions would get a 2 psi regulator.
Distance from your home to the main line.
The center of the meter must be 44 to 66 inches off the ground.
Gas meter regulator vent clearance distance to windows attic vent crawl space vent soffit vent.
Where i used to work the regular houses 3 bedroom 2 baths all had 1 4 psi at the meter.
A position perpendicular to the pipe indicates a closed valve but you should double check by confirming that the meter is no longer moving when a appliance is using gas.
1 foot to a feature located below.
The gas company states my meter can handle the additional requirement of the generator along with my other appliances.
Or maybe he said 15 20 psi.
Gas supplier private company public municipality or co op.
The valve will be at your gas meter on the side of your house and should shut off entirely with a quarter turn.
3 feet in any direction horizontally or vertically to the feature.
Gas line installation costs 12 to 25 per linear foot.
Turn off the gas to your house.
I think he said 20 psi.
A gas company guy once told me that the gas mains in that area were like 20 psi.
The piping upstream of the gas meter and the meter itself usually are the responsibility of the gas company.
Always check with your local gas company about lines and meters outside.
Repairs are 6 to 7 per foot.
Obstructions like a highway or building.
I would like to make a t connection right after the meter in the output side of the meter 1 1 4 gas line.
It uses 140 000 btu or 140 cf.
Often the line up to and including the gas meter is installed owned and maintained by the gas company.
There are four screws on each of the box s corners.
Open a knock out on top of the meter box to fit the riser pole width.
If the service entrance includes the circuit breaker the highest switch may not be more than 79 inches from the ground.
The service entrance must not be located within 3 feet of the utility side of the gas meter or within 10 inches of the customer side of the gas meter.
Section 2 4 2 gas meter set locations pdf 3 3 mb section 2 4 2 d electric and gas meter set separation dimensions and clearances figure 2 19 pdf 3 3 mb section 2 4 2 d gas meter set clearance from building openings figure 2 20 pdf 3 3 mb j 16 gas meter room pdf 123 kb j 95 meter guard design and installation arrangement pdf.
Gas meter regulator vent clearance to electrical devices such as switches electrical receptacles power disconnects.
3 feet in any direction to the feature.
Restaurants too needed the gas stepped up.
Insert the meter box into the riser pipe then secure it with a connector and a locknut of the same size as the pipe used.