Gas regulator in attic.
The inspector will or should know the details your plumbing code book fuel gas section may have info on venting gas regulators as well.
3 feet in any direction horizontally or vertically to the feature.
Basically the air trapped in the void when it was assembled.
If the top of the regulator was sealed then the diaphram inside would resist movement due to there being an increase of pressure resisting against it.
Regulators not equipped with a vent limiting means shall be permitted to be vented either directly to the outdoors or to a point within the top 1 foot 305 mm of the chase.
Gas meter regulator vent clearance distance to windows attic vent crawl space vent soffit vent.
This piping material is flexible so it bends easily to route around bracing or other obstacles and make turns.
3 feet in any direction to the feature.
Summary dom is spot on on both the regulator and the vent limiter if present requiring to be not only replaced due to the fouling of paint and loss of any certification but the entire set up needs to be reworked either installing vent piping or correcting the orientation and installing a line regulator not an appliance regulator properly selected for the range of pressures working pilot and non use and if using an automatic vent limiter instead of venting installed in the only.
Where gas distribution pressure in excess of 1 2 psig 3 4 kpa.
Typical gas regulator instructions require that the regulator be installed upright and horizontal that will leave a vent facing down but venting inside the building may be unsafe and illegal risking a fire or explosion.
1 foot to a feature located below.
Many builders use csst in new construction including installations with pounds pressure delivered to regulators at each appliance.
Check with a licensed plumber or your building department.
Corrugated stainless steel tubing csst can be installed in the walls or in attic space for natural gas.
Gas meter piping supplying gas to a building at a pressure in excess of 1 2 psig 3 4 kpa gauge shall be provided with a regulator that will reduce the pressure of the gas to 1 2 psig 3 4 kpa gauge or less prior to entering the gas distribution piping in the building except where the use of higher pressure is permitted.
What s a gas regulator doing in the attic.
Gas meter regulator vent clearance to electrical devices such as switches electrical receptacles power disconnects.